<!DOCTYPE HTML PUBLIC "-//W3C//DTD HTML 4.01 Transitional//EN""http://www.w3.org/TR/html4/loose.dtd"> <HTML ><HEAD ><TITLE >comedi_from_phys</TITLE ><META NAME="GENERATOR" CONTENT="Modular DocBook HTML Stylesheet Version 1.79"><LINK REL="HOME" TITLE=" Comedi " HREF="index.html"><LINK REL="UP" TITLE=" Comedi Function Reference " HREF="x4629.html#FUNCTIONREFERENCE"><LINK REL="PREVIOUS" TITLE="comedi_to_physical" HREF="r5644.html"><LINK REL="NEXT" TITLE="comedi_from_physical" HREF="r5697.html"></HEAD ><BODY CLASS="REFENTRY" BGCOLOR="#FFFFFF" TEXT="#000000" LINK="#0000FF" VLINK="#840084" ALINK="#0000FF" ><DIV CLASS="NAVHEADER" ><TABLE SUMMARY="Header navigation table" WIDTH="100%" BORDER="0" CELLPADDING="0" CELLSPACING="0" ><TR ><TH COLSPAN="3" ALIGN="center" >Comedi: The <SPAN CLASS="emphasis" ><I CLASS="EMPHASIS" >Control and Measurement Device Interface</I ></SPAN > handbook </TH ></TR ><TR ><TD WIDTH="10%" ALIGN="left" VALIGN="bottom" ><A HREF="r5644.html" ACCESSKEY="P" >Prev</A ></TD ><TD WIDTH="80%" ALIGN="center" VALIGN="bottom" ></TD ><TD WIDTH="10%" ALIGN="right" VALIGN="bottom" ><A HREF="r5697.html" ACCESSKEY="N" >Next</A ></TD ></TR ></TABLE ><HR ALIGN="LEFT" WIDTH="100%"></DIV ><H1 ><A NAME="FUNC-REF-COMEDI-FROM-PHYS" ></A >comedi_from_phys</H1 ><DIV CLASS="REFNAMEDIV" ><A NAME="AEN5677" ></A ><H2 >Name</H2 >comedi_from_phys -- convert physical units to sample</DIV ><DIV CLASS="REFSYNOPSISDIV" ><A NAME="AEN5680" ></A ><H2 >Synopsis</H2 ><DIV CLASS="FUNCSYNOPSIS" ><P ></P ><A NAME="AEN5681" ></A ><PRE CLASS="FUNCSYNOPSISINFO" >#include <comedilib.h></PRE ><P ><CODE ><CODE CLASS="FUNCDEF" >lsampl_t comedi_from_phys</CODE >(double data, comedi_range * range, lsampl_t maxdata);</CODE ></P ><P ></P ></DIV ></DIV ><DIV CLASS="REFSECT1" ><A NAME="AEN5692" ></A ><H2 > Description </H2 ><P >Converts data given in physical units (data) into sample values (lsampl_t, between 0 and maxdata). The parameter rng represents the conversion information to use, and the parameter maxdata represents the maximum possible data value for the channel that the data will be written to.</P ><P >Conversion is not affected by out-of-range behavior. Out-of-range data parameters are silently truncated to the range 0 to maxdata.</P ><P > </P ></DIV ><DIV CLASS="NAVFOOTER" ><HR ALIGN="LEFT" WIDTH="100%"><TABLE SUMMARY="Footer navigation table" WIDTH="100%" BORDER="0" CELLPADDING="0" CELLSPACING="0" ><TR ><TD WIDTH="33%" ALIGN="left" VALIGN="top" ><A HREF="r5644.html" ACCESSKEY="P" >Prev</A ></TD ><TD WIDTH="34%" ALIGN="center" VALIGN="top" ><A HREF="index.html" ACCESSKEY="H" >Home</A ></TD ><TD WIDTH="33%" ALIGN="right" VALIGN="top" ><A HREF="r5697.html" ACCESSKEY="N" >Next</A ></TD ></TR ><TR ><TD WIDTH="33%" ALIGN="left" VALIGN="top" >comedi_to_physical</TD ><TD WIDTH="34%" ALIGN="center" VALIGN="top" ><A HREF="x4629.html#FUNCTIONREFERENCE" ACCESSKEY="U" >Up</A ></TD ><TD WIDTH="33%" ALIGN="right" VALIGN="top" >comedi_from_physical</TD ></TR ></TABLE ></DIV ></BODY ></HTML >