Sophie

Sophie

distrib > Fedora > 14 > x86_64 > by-pkgid > 5076dbd0a0183d3ad8923b10d3d9da0f > files > 7

fmit-0.99.2-1.fc14.x86_64.rpm

automatically build qm files from ts:
http://www.cmake.org/Wiki/CMake:How_To_Build_Qt4_Software

remove ConfigForm.png
update french translation

automatiser le seuil de réaction
automatiser d'autres choses ?

Add low-pass filter to avoid problems with high sampling rate

Fix bug (voir mail)

 1. Would it be possible to have a celeste offset i.e. where you could add a
 constant value (Hz) to every note: +5Hz to -5Hz , this would be usefull for
 tuning the celeste on the organ!

 2. Would it be possible to have the note names only using sharps i.e. A#, C#,
 D#, F#, G# this is what I have always encountered in the organ building
 world.
 - pouvoir passer d'un naming scheme � l'autre.

 3. I would really like to use fmit. But it doesn't compile with the newest
 version of Jack. It complains about "CaptureThread.cpp:(.text+0x7276):
 undefined reference to `jack_error_callback'". It does compile with an
 older version of Jack, but that version of Jack won't work with the
 version of FFADO that works with my audio interface. Any chance you
 could update fmit to compile with the newest version of Jack?

 4. (voir mail de Jean-Jacques Sacr�): probl�me de chargement d'un
 fichier de traduction. en effet, si PACKAGE_NAME correspond pas au path
 d'installation, �a marche pas. nouveaut� dans la lib qt ?

 5. (voir mail de wayne): implementer le low-pass filter

Two remarks (of details):

    - as also can be seen on your welcome page, to my knowledge, 329.6Hz
is E3 rather than E4: since I remarked this for the whole frequency
range, it's probably due to the lack of a minus one somewhere in an
integer part operation.

    - I found that the default sound level for incoming audio is very
low so that setting is first required before using fmit; possibly, it
would be set higher in the next release.


unification of scales system

volume à partir de la somme des harmoniques pas de la valeur max
	perceptive volume from weighted spectrum ? loudness ? de Bark ?
high pass with FIR
band pass ranges with low pass
tests corrects des working transport possibles
shortcuts

Doc
	speak about 50hz on web site FAQ
	Do not use a too big sampling rate. 22050Hz should be largely enough in most cases.

promotion
	look for translations

algo
	sep en bandes avec resampling ?
	Quantizer
		Viterbi
    Detection automatique de la présence d'un son

interface
	statistics
			average on last n secondes, throw too old notes
			keep the history of the note (not only an average over the note)
			be able to drop too short notes
			average of volume
			mean or median averaging
		post-process notes with Viterbi
	harm struct
		add inharmonicity values in cents
		phase
	DFT
		enveloppe LPC
		adapt win length to f0, proportional to nb_periods
	Spectrogram
	microtonal view
		autodetect octave
?		stretch scale view to the complet scale length (not always 12 !)
		create your own scales inside FMIT
	configure
?		'restore factory settings' bug for ui_chkJACKAutoConnect and his source

code cleaning
	use AutoQSetting under Views

COMMANDS =======================================================================
lupdate ../ui ../src -ts fmit_fr.ts
lupdate ../ui ../src -ts fmit_de.ts
linguist tr/fmit_fr.ts
lrelease tr/fmit_fr.ts

cmake -DCMAKE_BUILD_TYPE:STRING=Debug