Sample Configurations for Brazil
================================

Here we provide sample working configurations for named Brazilian telco companies.
If you get you installation working with another telco not in this list or with
different params, please send me your config to alexandre.alencar@gmail.com.

All this settings should go to /etc/asterisk/chan_dahdi.conf or zapata.conf and
you need to choose only one sample per link.

Credits
=======

Many thanks to Evandro Arruda from ezVoice Telecom for it's contribution with
old PABX and telco samples. You can contact him at ecarruda@gmail.com or
evandro@ezvoice.com.br

Sample Configuration for Embratel
=================================

; Sample 1
signalling=mfcr2
mfcr2_variant=br
mfcr2_get_ani_first=no
mfcr2_max_ani=20
mfcr2_max_dnis=4
mfcr2_category=national_subscriber
; The next three params are for debuging, you can disable when in production
mfcr2_call_files=yes
mfcr2_logdir=embratel
mfcr2_logging=all

; Sample 2
signalling=mfcr2
mfcr2_variant=br
mfcr2_immediate_accept=no
mfcr2_get_ani_first=no   
mfcr2_max_ani=20
mfcr2_max_dnis=4
mfcr2_category=national_subscriber
mfcr2_mfback_timeout=1500
mfcr2_metering_pulse_timeout=-1
; choose only yes or no
mfcr2_allow_collect_calls=(no/yes)
mfcr2_double_answer=no
mfcr2_charge_calls=yes
mfcr2_forced_release=yes

Sample Configuration for Oi
===========================

; Sample 1
signalling=mfcr2
mfcr2_variant=br
mfcr2_get_ani_first=yes
mfcr2_max_ani=20
mfcr2_max_dnis=4
mfcr2_category=national_subscriber
; The next three params are for debuging, you can disable when in production
mfcr2_call_files=yes
mfcr2_logdir=oi
mfcr2_logging=all

; Sample 2
signalling=mfcr2
mfcr2_variant=br
mfcr2_get_ani_first=no
mfcr2_max_ani=20
mfcr2_max_dnis=20
mfcr2_category=national_subscriber
; The next three params are for debuging, you can disable when in production
mfcr2_call_files=yes
mfcr2_logdir=oi
mfcr2_logging=all

; Sample 3
signalling=mfcr2
mfcr2_variant=br
mfcr2_metering_pulse_timeout=500
mfcr2_get_ani_first=no
mfcr2_max_ani=20
mfcr2_max_dnis=20
mfcr2_category=national_subscriber
; The next three params are for debuging, you can disable when in production
mfcr2_call_files=yes
mfcr2_logdir=oi
mfcr2_logging=all


Sample Configuration for Brasil Telecom
=======================================

; Sample 1
signalling=mfcr2
mfcr2_variant=br
mfcr2_mfback_timeout=4000
mfcr2_get_ani_first=no
mfcr2_max_ani=20
mfcr2_max_dnis=4
mfcr2_category=national_subscriber
; The next three params are for debuging, you can disable when in production
mfcr2_call_files=yes
mfcr2_logdir=brt
mfcr2_logging=all

Sample Configuration for CTBC
=============================

; Sample 1
signalling=mfcr2
mfcr2_variant=br
mfcr2_immediate_accept=no
mfcr2_get_ani_first=no
mfcr2_max_ani=20
mfcr2_max_dnis=4
mfcr2_category=national_subscriber
; To fix issues with delay on international calls on this telco
mfcr2_mfback_timeout=3000
mfcr2_metering_pulse_timeout=-1
; choose only yes or no
mfcr2_allow_collect_calls=(no/yes)
mfcr2_double_answer=no
mfcr2_charge_calls=yes
mfcr2_forced_release=yes

Sample Configuration for Telefonica
===================================

; Sample 1
signalling=mfcr2
mfcr2_variant=br
mfcr2_immediate_accept=no
mfcr2_get_ani_first=no
mfcr2_max_ani=20
mfcr2_max_dnis=4
mfcr2_category=national_subscriber
mfcr2_mfback_timeout=3000
mfcr2_metering_pulse_timeout=-1
; choose only yes or no
mfcr2_allow_collect_calls=(no/yes)
mfcr2_double_answer=no
mfcr2_charge_calls=yes

Sample Configuration for Tadiran (PABX)
=======================================

; Sample 1

signalling=mfcr2
mfcr2_variant=br
mfcr2_immediate_accept=no
mfcr2_get_ani_first=no   
mfcr2_max_ani=10
mfcr2_max_dnis=20
mfcr2_category=national_subscriber
mfcr2_mfback_timeout=6000
mfcr2_charge_calls=yes

Sample Configuration for Digistar (PABX)
========================================

; Sample 1
signalling=mfcr2
mfcr2_variant=br
mfcr2_immediate_accept=no
; This PABX expect ANI first
mfcr2_get_ani_first=yes
mfcr2_max_ani=4
mfcr2_max_dnis=20
mfcr2_category=national_subscriber
mfcr2_mfback_timeout=6000
mfcr2_charge_calls=yes

Sample Configuration for Ericsson (PABX)
========================================

; Sample 1
signalling=mfcr2
mfcr2_variant=br  
mfcr2_immediate_accept=no
mfcr2_get_ani_first=no
mfcr2_max_ani=8
mfcr2_max_dnis=20
mfcr2_category=national_subscriber
mfcr2_mfback_timeout=3000
mfcr2_charge_calls=yes
; This PABX tends to bug without this
mfcr2_forced_release=yes

Sample Configuration for Avaya (PABX)
=====================================

; Sample 1
signalling=mfcr2
mfcr2_variant=br
mfcr2_immediate_accept=no
mfcr2_get_ani_first=no
mfcr2_max_ani=4
mfcr2_max_dnis=20
mfcr2_category=national_subscriber
mfcr2_mfback_timeout=1000
; To avoid call being dropped after 500ms
mfcr2_metering_pulse_timeout=2000
mfcr2_charge_calls=yes

Sample Configuration for Siemens HiPath (PABX)
================================================

; Sample 1
signalling=mfcr2
mfcr2_variant=br  
mfcr2_immediate_accept=no
mfcr2_get_ani_first=no
mfcr2_max_ani=8
mfcr2_max_dnis=20
mfcr2_category=national_subscriber
; Needed because this PABX delay digits forward
mfcr2_mfback_timeout=5000
mfcr2_charge_calls=yes
; This PABX tends to bug without this
mfcr2_forced_release=yes

Sample Configuration for Leucotron (PABX)
=========================================

; Sample 1
signalling=mfcr2   
mfcr2_variant=br
mfcr2_immediate_accept=no
mfcr2_get_ani_first=no
mfcr2_max_ani=8
mfcr2_max_dnis=20
mfcr2_category=national_subscriber
mfcr2_mfback_timeout=3000
mfcr2_charge_calls=yes