munipack-2.0.8-2.mga4.x86_64.rpm

.. C-Munipack - User's manual

   Copyright 2012 David Motl

   Permission is granted to copy, distribute and/or modify this document under the
   terms of the GNU Free Documentation License, Version 1.2 or any later version published
   by the Free Software Foundation; with no Invariant Sections, no Front-Cover Texts, and
   no Back-Cover Texts.

   $Id: konve_command.rst,v 1.1.1.1 2012/08/12 16:57:46 dmotl Exp $

.. program:: konve

.. index::
   pair: konve; command

.. _konve-command:
	
konve (command)
===============

utility for conversion of CCD frames to the FITS format


Synopsis
--------

konve [ options ] *input-files* ...


Description
-----------

The :command:`konve` command converts CCD frames from the format used by 
camera controlling software to FITS format. The correction of time of observation or image flipping 
can be applied also.

The program can be run in several modes, the mode is selected by command-line parameters. 
Besides the usual conversion mode, it allows printing header information of source files in short or 
detailed form. You can convert header only while not copying the image. Additional information, which
shall be written to the output files can be given in parameter file.

Current version of program supports reading SBIG (ST-xx) compressed and uncompressed files and the 
FITS files also. Note, that you can use FITS to FITS conversion for gathering files from many locations 
into one directory. It will solve the file name collisions.
		

.. _konve-input-files:

Input files
-----------

Names of input files can be specified directly on a command-line as command arguments; it is allowed to use the 
usual wild-card notation. In case the input files are placed outside the working directory, you have to specify 
the proper path relative to the current working directory.

Alternatively, you can also prepare a list of input file names in a text file, each input file on a separate line. 
It is not allowed to use the wild-card notation here. Use the -i option to instruct the program to read the file.


.. _konve-output-files:

Output files
------------

By default, output files are stored to the current working directory. Their names
are derived from the command name followed by a sequential number starting by 1.
Command options allows a caller to modify the default naming of output files.

The -o option sets the format string; it may contain a path where 
the files shall be stored to. Special meaning has a sequence of question marks, it 
is replaced by the ordinal number of a file	indented by leading zeros to the same
number of decimal places as the number of the question marks.

By means of the -i option, you can modify the initial value of a counter.

On request, the program can write a list of output files to a text file, use the -g option 
to specify a file name.


Options
-------

Options are used to provide extra information to customize the execution of a command. They are specified as command 
arguments.

Each option has a full form starting with two dashes and an optional short form starting with one dash only. Options 
are case-sensitive. It is allowed to merge two or more successive short options together. Some options require a value; 
in this case a value is taken from a subsequent argument. When a full form is used, an option and its value can also 
be separated by an equal sign. When a short form is used, its value can immediately follow the option.

Whenever there is a conflict between a configuration file parameter and an option of the same meaning, the option 
always take precedence.
			
.. option:: -n, --print-info

    print short info about frames; don't make any output file.
						
.. option:: -e, --print-header

    print content of the header; don't make any output file.
			
.. option:: -s, --set <name=value>

    set value of configuration parameter
			
.. option:: -p, --configuration-file <filepath>

    read parameters from given configuration file. See the :ref:`konve-configuration-file` section for 
    details.
			
.. option:: -i, --read-dirfile <filepath>

    read list of input files from specified file; see the :ref:`konve-input-files` section for details.
			
.. option:: -g, --make-dirfile <filepath>

    save list of output files to specified file, existing content of the file will be overwritten;
    see the :ref:`konve-output-files` section for details.
			
.. option:: -o, --output-mask <mask>

    set output file mask (default=:file:`kout????.fts`), see the :ref:`konve-output-files` section for details.
			
.. option:: -c, --counter <value>

    set initial counter value (default=1), see the :ref:`konve-output-files` section for details.
			
.. option:: -h, --help

    print list of command-line parameters
			
.. option:: -q, --quiet

    quiet mode; suppress all messages
			
.. option:: --version

    print software version string
			
.. option:: --licence

    print software licence
			
.. option:: --verbose

    verbose mode; print debug messages
			

.. _konve-configuration-file:

Configuration file
------------------

Configuration files are used to set the input parameters to the process that is going to be executed by a command. 
Use the -p option to instruct the program to read the file before other command-line options are processed.

The configuration file consists of a set of parameters stored in a text file. Each parameter is stored on a separate 
line in the following form: name = value, all other lines are silently ignored. Parameter names are case-sensitive.

.. confval:: flip-image =  xy

    flip image (value can be 'x', 'y' or 'xy')
			

Examples
--------

::

	konve -oout?.fts test1.st7 test2.st7 test3.st7
	
The command converts the files :file:`test1.st7`, :file:`test2.st7` 
and :file:`test3.st7` and writes the output to the files: :file:`out1.fts`, 
:file:`out2.fts` and :file:`out3.fts`.
			
Exit status
-----------

The command returns a zero exit status if it succeeds to process all specified files. Otherwise, it will stop 
immediately when an error occurs and a nonzero error code is returned.