Found UPS at /dev/usb/hid/hiddev0 hiddev driver version is 1.0.2 HID: vendor 0x51d product 0x2 version 0x6 app UPS HID: bus: 2 devnum: 2 ifnum: 0 UPS HID device name: "American Power Conversion Smart-UPS 1000 FW:600.1.I USB FW:1.2" Battery Chemistry: "PbAc" (4) InputReport 12 Field 0, app UPS, phys --- Usage 0, RemainingCapacity = 100 percent InputReport 8 Field 0, app UPS, phys --- Usage 0, RemainingTimeLimit = 0 Seconds InputReport 20 Field 0, app UPS, phys --- Usage 0, AudibleAlarmControl = 2 InputReport 7 Field 0, app UPS, phys --- Usage 0, Charging = 0 Field 1, app UPS, phys --- Usage 0, Discharging = 0 Field 2, app UPS, phys --- Usage 0, ACPresent = 1 Field 3, app UPS, phys --- Usage 0, BatteryPresent = 1 Field 4, app UPS, phys --- Usage 0, BelowRemainingCapacityLimit = 0 Field 5, app UPS, phys --- Usage 0, ShutdownRequested = 0 Field 6, app UPS, phys --- Usage 0, ShutdownImminent = 0 Field 7, app UPS, phys --- Usage 0, RemainingTimeLimitExpired = 0 Field 8, app UPS, phys --- Usage 0, CommunicationLost = 0 Field 9, app UPS, phys --- Usage 0, NeedReplacement = 0 Field 10, app UPS, phys --- Usage 0, Overload = 0 Field 11, app UPS, phys --- Usage 0, VoltageNotRegulated = 0 Field 12, app UPS, phys --- Usage 0, [ff860080] = 0 InputReport 22 Field 0, app UPS, phys Battery Usage 0, Test = 6 InputReport 23 Field 0, app UPS, phys Battery Usage 0, [ff860019] = 0 InputReport 27 Field 0, app UPS, phys Battery Usage 0, [ff86001a] = 3 InputReport 28 Field 0, app UPS, phys Battery Usage 0, [ff86001b] = 0 InputReport 21 Field 0, app UPS, phys Battery Usage 0, ManufactureDate = 11032 2001-08-24 InputReport 26 Field 0, app UPS, phys Battery Usage 0, RemainingTimeLimit = 120 InputReport 33 Field 0, app UPS, phys Input Usage 0, [ff860052] = 0 InputReport 34 Field 0, app UPS, phys Input Usage 0, [ff860061] = 2 InputReport 45 Field 0, app UPS, phys Output Usage 0, ConfigVoltage = 230 Volts InputReport 35 Field 0, app UPS, phys Output Usage 0, HighVoltageTransfer = 253 Volts InputReport 36 Field 0, app UPS, phys Output Usage 0, LowVoltageTransfer = 208 Volts InputReport 37 Field 0, app UPS, phys Output Usage 0, [ff86007e] = 0 InputReport 38 Field 0, app UPS, phys Output Usage 0, APCShutdownAfterDelay = 90 InputReport 54 Field 0, app UPS, phys --- Usage 0, AudibleAlarmControl = 2 InputReport 51 Field 0, app UPS, phys --- Usage 0, Charging = 0 Field 1, app UPS, phys --- Usage 0, Discharging = 0 Field 2, app UPS, phys --- Usage 0, ACPresent = 1 Field 3, app UPS, phys --- Usage 0, BatteryPresent = 1 Field 4, app UPS, phys --- Usage 0, BelowRemainingCapacityLimit = 0 Field 5, app UPS, phys --- Usage 0, ShutdownRequested = 0 Field 6, app UPS, phys --- Usage 0, ShutdownImminent = 0 Field 7, app UPS, phys --- Usage 0, RemainingTimeLimitExpired = 0 Field 8, app UPS, phys --- Usage 0, CommunicationLost = 0 Field 9, app UPS, phys --- Usage 0, NeedReplacement = 0 Field 10, app UPS, phys --- Usage 0, Overload = 0 Field 11, app UPS, phys --- Usage 0, VoltageNotRegulated = 0 Field 12, app UPS, phys --- Usage 0, [ff860080] = 0 FeatureReport 1 Field 0, app UPS, phys --- Usage 0, iProduct = 1 Smart-UPS 1000 FW:600.1.I USB FW:1.2 FeatureReport 2 Field 0, app UPS, phys --- Usage 0, iSerialNumber = 2 AS0134132215 FeatureReport 3 Field 0, app UPS, phys --- Usage 0, iManufacturer = 3 American Power Conversion FeatureReport 4 Field 0, app UPS, phys --- Usage 0, iOEMInformation = 3 American Power Conversion FeatureReport 5 Field 0, app UPS, phys --- Usage 0, iDeviceChemistry = 4 PbAc FeatureReport 6 Field 0, app UPS, phys --- Usage 0, Rechargeable = 1 Field 1, app UPS, phys --- Usage 0, CapacityMode = 2 percent FeatureReport 14 Field 0, app UPS, phys --- Usage 0, DesignCapacity = 100 percent Field 1, app UPS, phys --- Usage 0, FullChargeCapacity = 100 percent FeatureReport 12 Field 0, app UPS, phys --- Usage 0, RemainingCapacity = 100 percent FeatureReport 16 Field 0, app UPS, phys --- Usage 0, CapacityGranularity1 = 1 percent Field 1, app UPS, phys --- Usage 0, CapacityGranularity2 = 1 percent FeatureReport 15 Field 0, app UPS, phys --- Usage 0, WarningCapacityLimit = 50 percent FeatureReport 17 Field 0, app UPS, phys --- Usage 0, RemainingCapacityLimit = 10 percent FeatureReport 9 Field 0, app UPS, phys --- Usage 0, ManufactureDate = 11032 2001-08-24 FeatureReport 13 Field 0, app UPS, phys --- Usage 0, RunTimeToEmpty = 21000 Seconds FeatureReport 18 Field 0, app UPS, phys --- Usage 0, DelayBeforeShutdown = -1 FeatureReport 19 Field 0, app UPS, phys --- Usage 0, DelayBeforeReboot = -1 Seconds FeatureReport 8 Field 0, app UPS, phys --- Usage 0, RemainingTimeLimit = 0 Seconds FeatureReport 10 Field 0, app UPS, phys --- Usage 0, ConfigVoltage = 2400 CentiVolts FeatureReport 11 Field 0, app UPS, phys --- Usage 0, Voltage = 2754 CentiVolts FeatureReport 20 Field 0, app UPS, phys --- Usage 0, AudibleAlarmControl = 2 FeatureReport 7 Field 0, app UPS, phys --- Usage 0, Charging = 0 Field 1, app UPS, phys --- Usage 0, Discharging = 0 Field 2, app UPS, phys --- Usage 0, ACPresent = 1 Field 3, app UPS, phys --- Usage 0, BatteryPresent = 1 Field 4, app UPS, phys --- Usage 0, BelowRemainingCapacityLimit = 0 Field 5, app UPS, phys --- Usage 0, ShutdownRequested = 0 Field 6, app UPS, phys --- Usage 0, ShutdownImminent = 0 Field 7, app UPS, phys --- Usage 0, RemainingTimeLimitExpired = 0 Field 8, app UPS, phys --- Usage 0, CommunicationLost = 0 Field 9, app UPS, phys --- Usage 0, NeedReplacement = 0 Field 10, app UPS, phys --- Usage 0, Overload = 0 Field 11, app UPS, phys --- Usage 0, VoltageNotRegulated = 0 Field 12, app UPS, phys --- Usage 0, [ff860080] = 0 FeatureReport 22 Field 0, app UPS, phys Battery Usage 0, Test = 6 FeatureReport 23 Field 0, app UPS, phys Battery Usage 0, [ff860019] = 0 FeatureReport 27 Field 0, app UPS, phys Battery Usage 0, [ff86001a] = 3 FeatureReport 28 Field 0, app UPS, phys Battery Usage 0, [ff86001b] = 0 FeatureReport 21 Field 0, app UPS, phys Battery Usage 0, ManufactureDate = 11032 2001-08-24 FeatureReport 24 Field 0, app UPS, phys Battery Usage 0, RemainingCapacity = 1000 percent FeatureReport 26 Field 0, app UPS, phys Battery Usage 0, RemainingTimeLimit = 120 FeatureReport 25 Field 0, app UPS, phys Battery Usage 0, RunTimeToEmpty = 21000 FeatureReport 30 Field 0, app UPS, phys Battery Usage 0, Temperature = 3001 Degrees K with -1 exponent FeatureReport 31 Field 0, app UPS, phys Battery Usage 0, ConfigVoltage = 2400 CentiVolts FeatureReport 29 Field 0, app UPS, phys Battery Usage 0, Voltage = 2754 CentiVolts FeatureReport 32 Field 0, app UPS, phys Input Usage 0, Voltage = 2304 DeciVolts FeatureReport 33 Field 0, app UPS, phys Input Usage 0, [ff860052] = 0 FeatureReport 34 Field 0, app UPS, phys Input Usage 0, [ff860061] = 2 FeatureReport 44 Field 0, app UPS, phys Output Usage 0, PercentLoad = 0 FeatureReport 42 Field 0, app UPS, phys Output Usage 0, Frequency = 5000 CentiHertz FeatureReport 43 Field 0, app UPS, phys Output Usage 0, Voltage = 2304 DeciVolts FeatureReport 45 Field 0, app UPS, phys Output Usage 0, ConfigVoltage = 230 Volts FeatureReport 35 Field 0, app UPS, phys Output Usage 0, HighVoltageTransfer = 253 Volts FeatureReport 36 Field 0, app UPS, phys Output Usage 0, LowVoltageTransfer = 208 Volts FeatureReport 37 Field 0, app UPS, phys Output Usage 0, [ff86007e] = 0 FeatureReport 38 Field 0, app UPS, phys Output Usage 0, APCShutdownAfterDelay = 90 FeatureReport 39 Field 0, app UPS, phys Output Usage 0, DelayBeforeShutdown = -1 FeatureReport 40 Field 0, app UPS, phys Output Usage 0, DelayBeforeStartup = -1 Seconds FeatureReport 41 Field 0, app UPS, phys Output Usage 0, DelayBeforeReboot = -1 Seconds FeatureReport 46 Field 0, app UPS, phys --- Usage 0, iProduct = 5 Smart-UPS 1000 FeatureReport 47 Field 0, app UPS, phys --- Usage 0, iSerialNumber = 2 AS0134132215 FeatureReport 48 Field 0, app UPS, phys --- Usage 0, iManufacturer = 3 American Power Conversion FeatureReport 49 Field 0, app UPS, phys --- Usage 0, iName = 6 UPSIDEN FeatureReport 52 Field 0, app UPS, phys --- Usage 0, APC_UPS_FirmwareRevision = 7 FeatureReport 55 Field 0, app UPS, phys --- Usage 0, APC_USB_FirmwareRevision = 8 FeatureReport 50 Field 0, app UPS, phys --- Usage 0, APCPanelTest = 1 FeatureReport 53 Field 0, app UPS, phys --- Usage 0, ManufactureDate = 11032 2001-08-24 FeatureReport 62 Field 0, app UPS, phys --- Usage 0, [ff860027] = 0 FeatureReport 63 Field 0, app UPS, phys --- Usage 0, [ff860028] = 0 FeatureReport 54 Field 0, app UPS, phys --- Usage 0, AudibleAlarmControl = 2 FeatureReport 51 Field 0, app UPS, phys --- Usage 0, Charging = 0 Field 1, app UPS, phys --- Usage 0, Discharging = 0 Field 2, app UPS, phys --- Usage 0, ACPresent = 1 Field 3, app UPS, phys --- Usage 0, BatteryPresent = 1 Field 4, app UPS, phys --- Usage 0, BelowRemainingCapacityLimit = 0 Field 5, app UPS, phys --- Usage 0, ShutdownRequested = 0 Field 6, app UPS, phys --- Usage 0, ShutdownImminent = 0 Field 7, app UPS, phys --- Usage 0, RemainingTimeLimitExpired = 0 Field 8, app UPS, phys --- Usage 0, CommunicationLost = 0 Field 9, app UPS, phys --- Usage 0, NeedReplacement = 0 Field 10, app UPS, phys --- Usage 0, Overload = 0 Field 11, app UPS, phys --- Usage 0, VoltageNotRegulated = 0 Field 12, app UPS, phys --- Usage 0, [ff860080] = 0 Waiting for events ... (interrupt to exit)