<B>Manufacturer</B>: AT&T Paradyne<BR>
<B>Model</B>: 3710-Ax (<I>aka</I> DataPort)<BR>
<B>Latest Firmware Revision Tried</B>: 1.76.00<BR>
<B>Recommended Firmware Revisions</B>: 1.76.00<BR>
<B>Last Updated</B>: Date: 1998/10/12 20:47:51 $<BR>
<HR WIDTH=65% ALIGN=left SIZE=4>
</UL>

<DL COMPACT>
<DT><IMG SRC="../icons/info_icon.gif" ALT="o">
<DD>There is an
<A HREF="http://www.whnet.com/wolfgang/att.html">FAQ specifically for AT&T modems</A>.
<DT><IMG SRC="../icons/smiley.gif" ALT="o">
<DD>This modem is recommended for use with HylaFAX
<EM>only when used in Class 1</EM>.
</DL>

<HR WIDTH=65% ALIGN=right>
<B><A NAME="Class1"><FONT SIZE=+2>C</FONT>LASS 1 <FONT SIZE=+1>S</FONT>UPPORT</A></B>

<UL>
<LI>received HDLC frames do <EM>not</EM>
include the FCS bytes (<I>revs prior to 1.33</I>)
<LI>carrier is sometimes dropped w/o notice during receive (<I>rev 1.33</I>)
<LI>the command "<TT>ATH+FCLASS=0;A</TT>"
does not do the right thing because the command parser does not parse
the "<TT>;A</TT>"
<LI>the modem returns "<TT>OK</TT>" instead of
"<TT>NO CARRIER</TT>" or "<TT>NO ANSWER</TT>" when a
  dial attempt times out before carrier is established
</UL>

<HR WIDTH=65% ALIGN=right>
<B><A NAME="Class2"><FONT SIZE=+2>C</FONT>LASS 2 <FONT SIZE=+1>S</FONT>UPPORT</A></B>

<UL>
<LI>Result strings for
<TT>AT+FDCC=?</TT> and <TT>AT+FDIS=?</TT>
are semantically incorrect;
  ranges are returned as (a,b) instead of (a-b); e.g. (0,5) instead
  of (0-5) for signalling rate; this causes problems in deducing the
  true set of modem capabilities
(<I>old firmware revs</I>)
<LI>The modem sends the host ^S/^Q during page
data transmission (<TT>AT+FDT</TT>)
  even when RTS/CTS flow control is enabled.
<LI>Prior to rev 1.76 it was not possible to
disable copy quality checking (<TT>AT+FCQ=0</TT> failed).
<LI>There is no support for transmission of 2D-encoded data
<LI>In certain revisions,
the modem was observed to enter a state where it repeatedly sent
  EOP when commanded to send MPS (for <TT>AT+FET=0</TT>); power-cycling the
  modem cleared this condition
<LI>In certain revisions prior to 1.76,
when transmitting, the modem drops page data
(due to improperly priming the datapump).
<LI>The modem returns "<TT>OK</TT>" instead of
"<TT>NO CARRIER</TT>" or "<TT>NO ANSWER</TT>" when a
  dial attempt times out before carrier is established
<LI>In firmware revision 1.76, <TT>AT+FREV?</TT> can return gibberish that
causes the fax software to be unable to initialize the modem; to workaround
the problem set the <B>ModemRevQueryCmd</B>
configuration parameter to <TT>"!C01.1.76"</TT> (so the command
is not sent to the modem).
</UL>

<P>
<A HREF="index.html"><IMG SRC="../icons/contents.gif"
HEIGHT="20" WIDTH="20" ALT=" Back to Modem Index "> Modem Index</a>
<A HREf="digicom-scout.html"><IMG SRC="../icons/next.gif"
HEIGHT="20" WIDTH="20" ALT=" Next Modem in List "> Digicom Scout+</A>
<HR>

<ADDRESS>
<A HREF="mailto:webmaster@hylafax.org">webmaster@hylafax.org</A>.
Last updated $Date: 1999/12/03 00:10:33 $.
</ADDRESS>

</BODY>
</HTML>