<HTML> <HEAD> <TITLE>Telebit WorldBlazer/T3000 FAX Commands</TITLE> </HEAD> <BODY> <BASEFONT SIZE=4> <B><FONT SIZE=+3>T</FONT>ELEBIT <FONT SIZE=+1>W</FONT>ORDLBLAZER/<FONT SIZE=+1>T</FONT>3000 <FONT SIZE=+1>FAX</FONT> <FONT SIZE=+2>C</FONT>OMMANDS</B> <BASEFONT SIZE=3> <HR SIZE=4> Here's the revised commands for the WorldBlazer and T3000 modems for FAX. The current version without "adaptive answer and V.17" is LA7.05C. Starting with LA7.20M (released) adaptive answer and V.17 apply. If you have LA7.20 code prior to version M, please contact <A HREF="mailto:modems@Telebit.COM">modems@Telebit.COM</A>. <P> <HR WIDTH=65% ALIGN=right> <B><FONT SIZE=+2>C</FONT>OMMAND <FONT SIZE=+2>D</FONT>ESCRIPTIONS</FONT></B> <PRE> +FAA, Answer Parameter +FAA=? 0 +FAA=0 Starting with LA7.20M, the following is true: +FAA=? 0,1 +FAA=0 +FAA=1 _______________________________________ +FAXERR, T.30 Session Error Report +FAXERR=<table value>, read only Valid values: 0-255 Mandatory values: 0,10,20,30,40,50,60,70 0 = Normal and proper end of connection 10 = Unspecified Phase A error 20 = Unspecified Transmit Phase B error 30 = - 40 = Unspecified Transmit Phase C error 50 = Unspecified Transmit Phase D error 60 = - 70 = Unspecified Receive Phase B error _______________________________________ +FBADLIN, Bad Line Threshold +FBADLIN=? 0 +FBADLIN=0 _______________________________________ +FBADMUL, Error Threshold Multiplier +FBADMUL=? 0 +FBADMUL=0 . _______________________________________ +FBOR, Data Bit Order +FBOR=? 0-3 +FBOR=0 +FBOR=1 +FBOR=2 +FBOR=3 _______________________________________ +FBUF, Buffer Size +FBUF=0 _______________________________________ +FBUG, Session Message Reporting +FBUG=? 0,1 +FBUG=0 +FBUG=1 _______________________________________ +FCIG, Local Polling ID String +FCIG=? (20)(32-127) +FCIG="<local polling ID string>" _______________________________________ +FCLASS, Service Class Identification & Selection +FCLASS=? 0,2 +FCLASS=0 +FCLASS=2 _______________________________________ +FCQ, Copy Quality Checking +FCQ=? 0 +FCQ=0 _______________________________________ +FCR, Capability to Receive +FCR=? 0,1 +FCR=0 +FCR=1 _______________________________________ +FCTCRTY, CTC Retry Count +FCTCRTY=? 0 +FCTCRTY=0 _______________________________________ +FDCC, DCE capabilities parameters +FDCC=<VR,BR,WD,LN,DF,EC,BF,ST> +FDCC=? (0,1),(0-3),(0-2),(0-2),(0),(0),(0),(0-7) +FDCC? 0,3,0,2,0,0,0,0 Default Value Starting with Version LA7.20M the following is true: +FDCC=? (0,1),(0-5),(0-2),(0-2),(0),(0),(0),(0-7) +FDCC? 0,5,0,2,0,0,0,0 Values: VR 0,1 BR 0,1,2,3 (Starting with LA7.20M values are 0,1,2,3,4,5) WD 0,1,2 LN 0,1,2 DF 0 EC 0 BF 0 ST 0,1,2,3,4,5,6,7 _______________________________________ +FDCS, Current Session results +FDCS=<VR,BR,WD,LN,DF,EC,BF,ST> +FDCS? 0,0,0,0,0,0,0,0 Default value. _______________________________________ +FDFFC, Data Compression Format Conversion +FDFFC=? 0 +FDFFC=0 _______________________________________ +FDIS, Current Session Parameters +FDIS=<VR,BR,WD,LN,DF,EC,BF,ST> +FDIS=? (0,1),(0-3),(0-2),(0-2),(0),(0),(0),(0-7) +FDIS? 0,3,0,2,0,0,0,0 Default value Starting with Version LA7.20M the following is true: +FDIS=? (0,1),(0-5),(0-2),(0-2),(0),(0),(0),(0-7) +FDIS? 0,5,0,2,0,0,0,0 Values: VR 0,1 BR 0,1,2,3 (Starting with Version LA7.20M values are 0,1,2,3,4,5) WD 0,1,2 LN 0,1,2 DF 0 EC 0 BF 0 ST 0,1,2,3,4,5,6,7 _______________________________________ +FDR, Begin or Continue Phase C Receive Data +FDR _______________________________________ +FDT, Data Transmission +FDT _______________________________________ +FECM, Error Correction Mode Control +FECM=? 0 +FECM=0 _______________________________________ +FET, Transmit Page Punctuation +FET=? 0,1,2,4,5,6 Values: 0 1 2 4 5 6 _______________________________________ +FK, Session Termination +FK _______________________________________ +FLID, Local ID String +FLID=? (20)(32-127) +FLID="local ID string" _______________________________________ +FLNFC, Page Length Format Conversion +FLNFC=? 0 +FLNFC=0 _______________________________________ +FLPL, Indicate Document to Poll +FLPL=? 0,1 +FLPL=0 +FLPL=1 _______________________________________ +FMDL?, Request Model Identification +FMDL? _______________________________________ +FMFR?, Request Manufacturer Identification +FMFR? response: Telebit _______________________________________ +FMINSP, Minimum Phase C Speed +FMINSP=? 0-3 +FMINSP=0 +FMINSP=1 +FMINSP=2 +FMINSP=3 Starting with Version LA7.20M, the following is also true: +FMINSP=4 +FMINSP=5 _______________________________________ +FPHCTO, DTE Phase C Response Time-out +FPHCTO=? 0-255 +FPHCTO? 30 Default value. Range:0 - 255 _______________________________________ +FPTS, Page Transfer Status +FPTS=? 1-5 +FPTS=1 +FPTS=2 +FPTS=3 +FPTS=4 +FPTS=5 _______________________________________ +FRBC, Phase C Receive Data Block Size +FRBC=? 0-0 +FRBC=0 _______________________________________ +FREL, Phase C Received EOL Alignment +FREL=? 0,1 +FREL=0 +FREL=1 _______________________________________ +FREV?, Request Product Revision Identification +FREV? _______________________________________ +FSPL, Request to Poll +FSPL=? 0,1 +FSPL=0 +FSPL=1 _______________________________________ +FTBC, Phase C Trasmit Data Block Size +FTBC=0 _______________________________________ +FVRFC, Vertical Resolution Format Conversion +FVRFC=? 0 +FVRFC=0 _______________________________________ +FWDFC, Page Width Format Conversion +FWDFC=? 0 +FWDFC=0 RESPONSE DESCRIPTIONS _______________________________________ +FCFR, Indicate Confirmation to Receive +FCFR _______________________________________ +FCKG:<string>, Report the Remote ID +FCKG:"<CIG ID string>" Polling station ID +FCKG _______________________________________ +FCON, Facsimile Connection Response +FCON Starting with Version LA7.20M, the following is also true: When +FAA=1 is set, the modem will respond with FAX prior to reporting +FCON if a FAX call is detected. If a data call is detected, the response would be DATA followed by the CONNECT response. The CONNECT response is controled by the Q, X and S59 register settings. _______________________________________ +FCSI:<string>, Report the remote ID +FCSI:"<CSI ID string>"Called Station ID +FCSI _______________________________________ +FDCS, Report DIS/DCS/DTC frame information +FDCS=<VR,BR,WD,LN,DF,EC,BF,ST> +FDCS? 0,0,0,0,0,0,0,0 Default value. _______________________________________ +FHNG, Call Termination with Status +FHNG:<hang-up status code> _______________________________________ +FPOLL, Remote Polling Indication +FPOLL _______________________________________ +FPTS, Receive and Transmit Page Transfer Status +FPTS=? 1-5 +FPTS=1 +FPTS=2 +FPTS=3 +FPTS=4 +FPTS=5 _______________________________________ +FTSI:<string>, Report the Remote ID +FTSI:"<TSI ID string>"Transmit Station ID </PRE> <A HREF="@HTMLPATH@/Modems/telebit-t3000.html"><IMG SRC="@HTMLPATH@/icons/back.gif"> Return to Telebit Worldblazer/T300 information</A>. <HR> <ADDRESS> Jaime Sainez / <A HREF="mailto:modems@Telebit.COM">modems@Telebit.COM</A>. Last updated $Date: 1998/10/12 20:47:51 $. </ADDRESS></A> </BODY> </HTML>