libhylafax4.1.1-devel-4.1.5-1mdk.ppc.rpm

<HTML>
<HEAD>
<TITLE>Digicom Scout+</TITLE>

<BODY>

<BASEFONT SIZE=4>
<B><FONT SIZE=+3>D</FONT>IGICOM <FONT SIZE=+2>S</FONT>COUT+</B>
<BASEFONT SIZE=3>

<UL>
<HR WIDTH=65% ALIGN=left SIZE=4>
<B>Manufacturer</B>: Digicom Systems<BR>
<B>Model</B>: Scout+<BR>
<B>Latest Firmware Revision Tried</B>: 3507/3506<BR>
<B>Recommended Firmware Revisions</B>: 2A19/2931<BR>
<B>Last Updated</B>: Date: 1998/10/12 20:47:51 $<BR>
<HR WIDTH=65% ALIGN=left SIZE=4>
</UL>

<DL COMPACT>
<DT><IMG SRC=../icons/info_icon.gif" ALT="o">
<DD>There is online
<A HREF="http://www.whnet.com/wolfgang/scout.html">documentation</A>
and an
<A HREF="http://www.whnet.com/wolfgang/digicom.html">FAQ for Digicom modems</A>.
</DL>

<HR WIDTH=65% ALIGN=right>
<B><A NAME="Class1"><FONT SIZE=+2>C</FONT>LASS 1 <FONT SIZE=+1>S</FONT>UPPORT</A></B>

<UL>
<LI><TT>AT+FMFR?</TT>,
<TT>AT+FMDL?</TT>,
and
<TT>AT+FREV?</TT> all return "<TT>3</TT>" in some versions of firmware
(where vestiges of Class 2 support were present)
<LI><TT>ATS17=2</TT> can be used to force 1300 Hz CNG tones to be sent (the
  register is not documented)
<LI>
RTS/CTS is not honored while sending page data; software flow
  control must be used (<TT>AT*F2</TT>).
  This is fixed in rev 3507/3506 firmware
  by adding a register <TT>S24</TT> that can be used to control flow control
  in facsimile mode:
<DL>
<DD>0 means use XON/XOFF,
<DD>1 means use RTS/CTS, and
<DD>2 means use whatever is specified by AT*F.
</DL>
Note however that <TT>S24</TT>
  is not permanent; it is reset after each disconnect.  On power on
  <TT>S24</TT> is 0.  <TT>S24</TT> is unchanged by <TT>AT&F</TT>.
<LI>Receiving at 4800 baud v.27 does not work correctly; received
  data is garbage
  (<I>fixed in firmware revision 3225/3310</I>).
<LI>Commands must not be sent to the modem too fast, no more than
  every 50ms (or more) depending on what the modem is doing.
<LI>The modem gets confused by receivers that assert a data
  carrier before sending CED; a <TT>+FCERROR</TT> result is returned before
  usually returning "<TT>NO CARRIER</TT>"; this can sometimes be overcome
  by sending 1300 Hz CNG tones instead of the normal 1100 Hz tones.
</UL>

<P>
<A HREF="index.html"><IMG SRC="../icons/contents.gif"
HEIGHT="20" WIDTH="20" ALT=" Back to Modem Index "> Modem Index</a>
<A HREf="everex-2496d.html"><IMG SRC="../icons/next.gif"
HEIGHT="20" WIDTH="20" ALT=" Next Modem in List "> Everex 24/96D</A>
<HR>

<ADDRESS>
<A HREF="mailto:webmaster@hylafax.org">webmaster@hylafax.org</A>.
Last updated $Date: 1999/12/03 00:10:33 $.
</ADDRESS>

</BODY>
</HTML>