<B><FONT SIZE="+3">Z</FONT>YXEL <FONT SIZE="+2">C</FONT>OMMUNICATIONS <FONT SIZE="+1">U-1496</FONT></B>
<BASEFONT SIZE=3>

<UL>
<HR WIDTH="65%" ALIGN=left SIZE=4>
<B>Manufacturer</B>: ZyXEL Communications Inc.<BR>
<B>Model</B>: ZyXEL U-1496<BR>
<B>Latest Firmware Revision Tried</B>:
    V 6.19 M<BR>
<B>Recommended Firmware Revisions</B>:
    V 6.19 M<BR>
<B>Last Updated</B>: Date: 1999/03/28 21:22:11 $<BR>
<HR WIDTH="65%" ALIGN=left SIZE=4>
</UL>

<DL COMPACT>
<DT><IMG SRC="../icons/info_icon.gif" ALT="o">
<DD>Includes
<A HREF="ZyXEL/voice.html">support for digitized voice</A>.
<DT><IMG SRC="../icons/info_icon.gif" ALT="o">
<DD>The first modem with working Class 2.0 support.
<DT><IMG SRC="../icons/smiley.gif" ALT="o">
<DD>This modem is recommended for use with HylaFAX <EM>
only with firmware revision 6.19 or later</EM>.
</DL>

<HR WIDTH="65%" ALIGN=right>
<B><A NAME="Class2"><FONT SIZE="+2">C</FONT>LASS 2 <FONT SIZE="+1">S</FONT>UPPORT</A></B>

<P>
<EM>Most of the problems/issues found were fixed
in the rev 6.13 firmware.</EM>


<HR WIDTH="65%" ALIGN=right>
<B><A NAME="Class2.0"><FONT SIZE="+2">C</FONT>LASS 2.0 <FONT SIZE="+1">S</FONT>UPPORT</A></B>

<UL>
<LI>Several comments have been made to the mailing-list to say that this modem suffers
    particularly from the <I>retrain negative problem</I> [ will send the first page three
    times, then abort ].
<LI>However, the latest firmware, <B>v6.19</B>, has been reported to solve this issue; and
    the modem can be recommended for use with HylaFAX with this firmware revision or later.
<LI>Problems were reported with the <b>1496EG+</b> model available in the
    German market. The advice was to <i>get an old dusty 1496E</i>.
<LI>A <i>99.8%</i> error free rate was the result of lowering the baud rate
    to 19200 in both the <TT>ModemRate</TT> as well as the <b>S18</b> register.
    These are the necessary additions to the modem config file:
<PRE>
# Additional reset commands:
#
# &B1         DTE-DCE rate is fixed at DTE setting
# &N0         Auto-negotiate highest possible DCE-DCE link rate
# &S0         DSR always on
# *F0         Deny remote configuration
# S18=3       Receive at 19200
# S38.3=1     DCD on/off sequence follows UNIX standard; also
#             fix receiving baud rate at S18 value
# S39=0       (avoid Class 2 compatibility hacks)
#
ModemResetCmds:      AT&B1&N0&S0*F0S18=3S38.3=1S39=0
#
</PRE>
</UL>

<P>
<!--htdig_noindex-->
<A HREF="index.html"><IMG SRC="../icons/contents.gif" 
HEIGHT="20" WIDTH="20" ALT=" Back to Modem Index "> Modem Index </A>
<A HREf="zyxel-elite.html"><IMG SRC="../icons/next.gif"
HEIGHT="20" WIDTH="20" ALT=" Next Modem in List "> Zyxel Elite 2864 and 2864I</A>
<!--/htdig_noindex-->
<HR>

<ADDRESS>
<A HREF="mailto:webmaster@hylafax.org">webmaster@hylafax.org</A>.
Last updated $Date: 1999/07/26 20:42:52 $.
</ADDRESS>

</BODY>
</HTML>